Lo Primero es Primero, La Seguridad de Las Personas, La Naturaleza y Máquinas, Gestión Seguridad Eléctrica,

                                                            Análisis, Planificación, Diseño, Desarrollo, Puesta en Marcha, Mantenimiento y Control 

                      La Electricidad es Peligrosa, su Ausencia también (By Bender).

The products are reliable, simple and convenient, intelligent management that provide all-in-one configurations for customers.

Big Data eraMicro & SmallMediumLargeIndustryContainerMonitoreo Calidad y Seguridad Energía Eléctrica



iLegend Container Data Center Solution

iLegend Container Data Center Solution


iLegend series container data center adopts integrated design (All-in-one), meeting the demand of outdoor small and medium-sized data center construction with fast deployment, fast delivery and flexible movement.

Big Data Era, You Need Green Data Center

Release time:2020-04-04

Click amount: 1315

Summary: When we browse the web, micro-blog and WeChat will be rather baffling out some ads, but the strange thing is that some advertisements do you need, in fact these ads are not careful, this is a big data analysis and the results of the use of.

We want to travel, vacation, booking air tickets, hotel online, always easily according to the specified time and place, the star to find the right target, and can be found to the scenic area more convenient hotel accommodation, and had maxed circle of friends of the Alipay bank's credit card bills, pay bills, and big data closely connected.

In the current data center industry in the application and rise of various big data technology, the amount of data presents a spurt of growth, as well as users of the data center business availability requirements also put forward new demands and changes. In this context, the construction of data center infrastructure is facing new challenges and opportunities, modular, intelligent, rapid expansion, flexible response, green environmental protection.

INVT modular data center infrastructure solutions

Modularization of infrastructure and Engineering

At present, the industry commonly used micro module data center is mainly used in indoor scenes, mainly by the end of the IT equipment, air conditioning, HVDC between columns and modular UPS, a micro channel cooling module products; container type data center is mainly used in outdoor scenes, including IT box, distribution box, cold box, Faxiang Chai box office, etc.. The former implements large-scale deployment, but is only used for IDC terminal devices, and lacks mobility. The latter is easy to move and flexible to build, but the scale is limited. Combining the two can build a large data center in a faster and more flexible way.

The data center of the main modules such as IT, the infrastructure (electricity, air conditioning, electricity etc.), engineering facilities (buildings, offices) according to the optimal model and construction method on the product of the standard interface, to form the pre prepared container products in the factory by the highway freight carrier, you can quickly move to the project site, and can be flexibly disassembled, built and moved to other venues recycling. In the project site, infrastructure and engineering supporting construction and deployment mode such as pile blocks, flexible construction site and construction cost are greatly reduced, and the data center construction is green construction cost are greatly reduced, and the data center construction is green.

In addition, the building structure is very simple, so the machine floor of the main building construction time can be greatly shortened, especially the frame structure and the large bay, the whole wall mosaic pattern room frame construction time is very short, large space structure and wall stitching mode not only construction progress, and building materials Recyclable use more green environmental protection, in addition to the relocation of large equipment out of the room area, is more suitable for the construction of large data center model. Because the room building structure is very simple, and large mechanical and electrical equipment mostly outside, so in the data center space utilization rate is very high, can put most of the floor space for placing the IT cabinet, so each cabinet volume ratio is very low, greatly enhance the utilization rate of the space in the room.

INVT - Tengzhi ITalent series of large integrated intelligent data center

Direct / indirect multi-mode natural refrigeration

The weather conditions permit area, when the outdoor temperature is lower than the indoor, the recommended way is commonly used by direct air cooling, the initial investment is low, the system is simple, obvious energy saving effect on regional natural conditions are good. But the fresh air enters the room directly, the temperature and humidity are difficult to control, resulting in a large number of condensed water and humidifying excessive energy consumption and bad dust removing effect, not in other chemical pollutants such as sulfide and phosphide.

In order to solve these problems, can be introduced into the indirect wind heat natural cooling, indirect natural cooling is the use of a air - air heat exchanger, the low temperature outdoor air through the heat exchanger to the indoor temperature and air, avoid the pollution caused by the external air directly into the room. At the same time, the air air heat transfer efficiency is reduced, the size of the heat exchange equipment is large, and the energy saving is affected. In order to further improve energy efficiency, indirect evaporation and natural evaporation combined with direct fresh air natural cooling, wind heat transfer, natural cooling and mechanical refrigeration can be used to flexibly select working modes in different scenes.

Direct fresh air natural cooling mode

When the outdoor temperature is low and the air quality is good in winter, the outdoor fresh air and indoor hot air can be mixed and filtered and sent into the computer room, which can reduce the energy consumption of air conditioning to the greatest extent.

Natural cooling mode of indirect wind and air heat transfer

In the case of low outdoor temperature in winter, in order to avoid the air quality problems caused by direct fresh air, the heat exchange between the return air and the outdoor cold air in the heat exchanger is carried out in the heat exchanger.

Indirect evaporative natural cooling model

In the spring and autumn season, the outdoor air temperature is low, because the outdoor air temperature is not low enough, the need for high-pressure micro mist spray adiabatic evaporation refrigeration way to supplement the amount of refrigeration.

Indirect evaporation natural cooling + mechanical cooling mode

In the summer, the outdoor temperature is high, through the high-pressure micro mist spray adiabatic evaporation refrigeration to supplement refrigeration, such as indoor air temperature through the heat exchanger after cooling still does not reach the requirements of air temperature, but also need to add mechanical refrigeration.

The introduction of indirect evaporative cooling scheme no compressor running mode, using water evaporation heat exchange principle, air and air heat away room heat, energy efficiency ratio of EER up to 16, is 5 times of compression refrigeration and air conditioning machinery, energy saving compared to conventional chiller cooling rate, the annual energy saving rate of >50%. INVT recommended indirect evaporation cooling scheme combined with fresh air, wind heat, mechanical refrigeration function, flexible work mode selection in different scenarios, to enhance the overall efficiency of energy use in the room.

New energy and uninterrupted power supply combined with direct power supply and distribution.

The data center has always been a big energy consumer, so many technology giants are trying to innovate in the introduction and application of new energy technology. Solar energy is one of the most widely used green new energy sources in cities with sufficient lighting. Solar photovoltaic power generation system consists of polysilicon components, in order to save installation space, can be installed in a modular data center top components are transversely arranged, and bracket with adjustable spacing adjustable angle function, the overall stent is simple, fast installation.

Photovoltaic power generation is affected by sunlight, there is power supply instability, data center power distribution can be combined with uninterruptible power supply, power grid connection mode using multi-channel redundancy scheme to achieve flexible switching overnight maintenance. According to different application scenarios, a variety of work modes can be flexibly selected:

Model one

The power supply of the server is customized according to the main power supply, and the main power supply of the two main power supply systems is connected with the direct supply of the city power supply and the connection of the photovoltaic and uninterruptible power supply (UPS);

Mode two

The server power supply is not divided into main and standby, photovoltaic and UPS grid connected with the city power supply directly, each half of the load

Mode three

Server power supply according to the main standby, photovoltaic and urban power grid connected with the UPS two power supply one main one standby;

Mode four

The power supply of the server is not divided into main and standby. After the grid connection of PV and city power, half load is carried out with UPS.

Due to the higher reliability and efficiency of the UPS, the HVDC scheme is preferred for uninterruptible power supply (HVDC). INVT suggestions on energy saving and reliability of distribution system considering.

The scheme of distribution logic is: the power input through the rectifier, HVDC output 270Vdc, PV output by DC/DC 270Vdc input, 2 output DC Road 1 road, controlled by the monitoring module, the AC PDU in hot standby state. The output of the circuit is supplied to the cabinet. During the day, the photovoltaic panel provides 100% power supply and charging the battery, AC PDU 0% reserve; at night, HVDC provides 100% power supply cabinet, and charging the battery, AC PDU 0% reserve; when the photovoltaic panels and HVDC at the same time the fault or maintenance, AC PDU power supply 100%. In order to make full use of photovoltaic power, the peak watt value of PV system is consistent with the peak load value.

The introduction of green energy photovoltaic power generation, the use of photovoltaic new energy and HVDC DC grid, combined with direct power supply and supply of urban power supply innovation program, can ensure the system reliability on the basis of greatly reducing the distribution energy consumption.

Intelligent management

Data center re construction, light operation and maintenance is the disadvantage of most projects. The long running life of operation and maintenance in data center plays a vital role in energy saving and reliability of the system. In order to reduce human errors, and to hand to the paper, the remote intelligent INVT monitoring system to achieve the following functions:

Modular, intelligent, rapid expansion, flexible response, green energy saving has always been the theme and soul of leading the change of data center. In the modular data center on the basis of the existing and proposed solutions of INVT MDC+ data center construction of green energy saving new generation module based on, put forward a number of innovative technologies to improve energy efficiency. Through the IT and supporting (infrastructure, engineering) modular product design, direct / indirect multi mode natural cooling refrigeration technology, energy and uninterruptible power supply with power grid direct power supply technology and remote monitoring technology is expected to achieve intelligent visualization of global PUE below 1.5, to provide reference for a new generation of modular data center infrastructure infrastructure construction.

Micro and Small Data Center

iSmart Series Integrated Cabinet Solution

iSmart Series Micro & Small Integrated Data Center Solution, also know as the mini & micro integrated data center, integrates UPS, air conditioner, power distribution module, monitoring system, temperature and humidity detection, light and access control in a standard 19-inch server cabinet. All equipment is pre-installed and precommissioned in the factory. The on-site installation is easy and convenient, which can realize rapid deployment, occupy less area, and comes with remote web interface monitoring function, which can realize remote operation and maintenance of a site.

Comparing to large data center, the structure of medium and small data center is similar. Most of the equipments are also critical loads and require very high reliability. The redundant rate may not as high as large data center, so the power reliability will have to rely on power supply itself. Besides of reliability, flexibility is one of the most important requirements because of the power upgrading possibility.

1. High power UPS system

2. Power distribution unit

3. Battery banks

4. Telecom DC power system

5. Monitoring system

Figure 1 shows INVT power solution for medium and small data center. Precision power supply system, air conditioning system and monitoring system are the main parts of the infrastructure. According to the exact requirements of different projects, UPS paralleling system or single unit can be the choice.

Figure 1: INVT solution for medium and small data center

The power source from the utility and the generator are ed by the ATS (automatic transfer switch) and connected to the central PDU (Power distribution unit). ATS will choose one of the sources to feed the connected equipments according to utility condition and customer setting. UPS, telecom DC power supply, and other equipments are connected to the central PDU. According to the requirements of different projects, people can choose central UPS power source or distributed UPS power source. Central UPS configuration usually applies one high power UPS system to feed all the critical loads, and distributed UPS configuration applies several UPSs for different kinds of loads.

The advantage of central UPS configuration is that the UPS and the battery banks are installed together, easy for management and maintenance, the disadvantage is that the power distribution is not flexible. In the case of distributed UPS configuration, the power distribution is flexible that people can choose different kinds of UPSs for different loads, but the management and maintenance of the system is complex.

INVT power offers the customer reliable and flexible solution for data center applications. In the case of central UPS configuration, INVT power recommends the modular UPS due to the upgrading requirements. If people choose distributed UPS configuration, INVT power recommends the tower UPS for the fixed loads, and modular UPS for the growing loads.

Large Data Center

Due to the fast increasing requirement of information management in all kinds of industries, people are building more and more large data centers all around the world. Usually the large data center is bigger than 500 m2 and the numbers of racks inside is a large number. The requirements for power system include high power, high reliability, easy for upgrading and etc.

1. High power UPS system

2. Power distribution unit

3. Battery banks

4. Telecom DC power system

5. Monitoring system

Figure 1 shows a sample diagram of large data center. The main infrastructure includes UPS, PDUs, air conditioners, DC power, lightning protection, monitoring system and etc. Due to the high reliability requirement, large data centers are usually built according to Tier4.

Figure 1: Diagram of larger data center

Due to the application of UPS and the redundant design of power distribution system, the power reliability of modern large data center is higher than ever. As the loads of data center are growing so fast that not only reliability but other issues we have to face on. Energy saving, flexible for upgrading, high power density, intelligent, all of these aspects are becoming more and more important for the modern data centers.

Figure Figure 2: INVT solution for large data center

Figure 2 shows INVT power solution for large data center. The power source from the utility and the generator are ed by the ATS (automatic transfer switch) and connected to the central PDU (Power distribution unit). ATS will choose one of the sources to feed the connected equipments according to utility condition and customer setting. UPS, telecom DC power supply, TVSS and other equipments are connected to the central PDU. INVT power provides the leading technology of LBS (Load bus synonization) system to insure the reliability of the system. The LBS system is considered to be the best configuration for the data center power solution. In the case of double power input loads, two UPS systems will feed with double power source. STS is needed for the single power input loads to one of the sources automatically.

The modular UPS from INVT power is very suitable for the requirements of the modern large data center. Besides the high reliability, INVT power modular UPS has the following advantages:

1. Modular design, decrease the initial investment of the customer.

2. Modular design, easy and flexible for system upgrading.

3. Very high system efficiency, energy saving technology.

4. Very high power density, save the precious space in the data center.

Industry Application

More and more precision equipments are applied in modern factories, and manufacturing process relies more and more on IT technologies, all of these bring the requirement of power supply reliability. The load types in modern factories are complex and different load may require different power condition. It’s important to choose suitable power supply for critical loads to insure the manufacturing process. Meanwhile, due to the factory field condition, the power supply protection degree and system function are also important.

1. UPS system

2. Power distribution unit

3. Battery banks

4. Monitoring system

According to the load type, the critical equipments in modern factories can be divided into the following: 

1. Precision industrial equipments, such as semiconductor packaging machine, SMT machine, etc.

2. Process management system, such as DCS system, remote monitoring and control system, etc.

3. Factory IT system, such as ERP, PLM, etc.

Figure 1 shows INVT Power solution for modern factory.

Figure 1: Solution for modern factory

The power source from the utility and the generator are ed by the ATS (automatic transfer switch) and connected to the PDU (Power distribution unit). ATS will choose one of the sources to feed the connected equipments according to utility condition and customer setting. Basically INVT power recommends the customer to separate the PDU for industrial loads and factory IT system. Generally speaking, UPS paralleling system is necessary for precision industrial load. In case of influence, the process management system can be separated by using independent UPS system.

According to different condition, the factory IT system can be powered by the same UPS system as process management system or an independent UPS system. Similar to datacenters, there are many growing loads in industrial application, so the flexibility of the power supply system is becoming more and more important.

Characteristics

Configure on demand and quickly deploy

INVT modular data center strictly follows international/domestic standards during planning and design, adopts modular design ideas, is highly integrated, and is easy to install.
The modular data center is partially pre-installed with cabinets before leaving the factory. You can use it after simple operations such as simple combination and placement of water and electricity and fixed cabinets.

Security management Intelligent and reliable

The modular data center follows the GB50174 standard, and the equipment is safe and reliable.
The modular data center is designed with full consideration of the ability to withstand natural disasters, and has reliable power and cold supply to ensure the normal operation of the communication network.
The modular data center is equipped with a complete monitoring system, which can know the environment and power environment of the computer room at any time, and improve the prevention and monitoring capabilities of the computer room.

Green and efficient, energy saving and environmental protection

The modular data center adopts precision air supply and sealed cold aisles to reduce energy consumption, avoid mixing of hot and cold air flows, and improve the efficiency of electric power usage.
Modular data centers improve the energy efficiency of data centers and reduce energy consumption by more than 30% compared with traditional data centers.

Flexible expansion and rapid response

Modular data center adopts modular design and can be flexibly configured to quickly adapt to site requirements.
The modular data center reserves a reasonable margin on the power supply and communication ports to achieve flexible expansion.

Integrated Data Center Solution. The Products are reliable, simple and convenient, intelligent management that provide all-in-one configurations for customers.

iLegend Container Data Center Solution

iLegend series container data center adopts integrated design (All-in-one), factory prefabricated installation, integrating power supply and distribution system, cooling system, IT cabinet, closed aisle system, monitoring system and fire extinguishing system in a container, forming a unit that can be operated independently, and the whole system is monitored and managed by eSite monitoring system, meeting the demand of outdoor small and medium-sized data center construction with fast deployment, fast delivery and flexible movement. ( watch the introduction video on YouTube )

Features

1. Factory prefabricated

2. 20ft/40ft standard container

3. All-in-one secure and reliable

4. IP55, automatic fire extinguishing system

Specifications

iLegend Container Data Center Product Specification
Unit40ft layout All-In-One solution20ft layout All-In-One solution
Cabinet SystemSize of IT cabinet(W×D×H)mm600×1200×2000600×1200×2000
Num. of IT cabinet(pcs)83
Power of each cabinet(kW)6/9(High density)6/9(High density)
Total power(kW)48/72(High density)18/27(High density)
Power and Distribution
System
Power supply system 250A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA  125A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA  
UPSModular Online UPS 90~150kVAModular Online UPS 40~90kVA
Battery back-up timeIn-row battery cabinet, the number of battery and capacity can be selected according to project requirements
PDU16 port IEC PDU(C13*12+C19*4),32A
Cooling SystemCooling method Default installation of 25kW air-cooled inverter in-row air conditioner(300mm wide)
Monitoring SystemPower and environment systemMonitoring host can realize the centralized monitoring of integrated power distribution cabinet, UPS, air conditioning, access control, video, fire, etc., and support sound and light, telephone, WeChat, SMS, e-mail multiple alarm methods
Access controlSupport IC card + password + fingerprint three-in-one access control system, optional face recognition
Local DisplaySupport 10.1 inch touch screen, support local touch screen, client, remote Web, mobile app and other display methods
Fire Prevention System Fire extinguishing systemAutomatic flooding fire extinguishing system, cold/hot aisles are equipped with smoke and temperature sensor, automatic control of fire gas release , support for sound and light, gas release indicator and other warning methods, support for manual emergency opening of the fire extinguishing system (optional Pipe fire extinguishers)
Fire extinguishing gasFM200/HFC-227ea (Novec 1230 optional)
Container Structure Container size(H×W×L)mm40ft:2896×2438×1219220ft:2896×2438×6058
Weight of container(T)84
Container load-bearing(T)157
Container protectionWaterproof, dustproof, anti-mold, protection grade:IP55
Operation EnvironmentAmbient temperature(℃)-40~50(-20 ℃ below require optional low temperature components and water pipes need to do insulation treatment)
Altitude(m)More than 1000m need to be derated

iWit Series Medium-Sized Integrated Data Center Solution

iWit Series Medium-Sized Integrated Data Center Solution

iWit Series Medium-Sized Integrated Data Center Solution


The Medium-Sized Integrated Data Center Solution integrates all needed equipment into cabinet with closed hot and cold aisles. The overall area of a single cabinet is 0.84㎡, which is suitable for computer rooms within 20-60 m2

INVT Network Power launches the iWit, a new addition to its Integrated Data Center Solution following the iSmart. iWit integrates a full set of power distribution functions and consists of three parts: one main cabinet +N* auxiliary cabinets+N*air conditrioners. The main cabinet includes monitoring module, LCD, PDU, UPS, etc. The auxiliary cabinet comes with a cabinet and a single cabinet control module as standard. We can provide customers with all options, and you can choose according to your needs. The capacity of a single cabinet≈3~10kVA, integrates all needed equipment into cabinet with closed hot and cold aisles. The overall area of a single cabinet is 0.84㎡, which is suitable for computer rooms within 20-60㎡. ( watch the introduction video on YouTube )

Features

Specifications

Application Case

Download

Customer Values:


1. Safe and reliable.


2. High efficiency and energy saving.


3. Rapid installation.


4. Intelligent management.


Core Features:


1. Saving 3U cabinet space.


2. Saving energy more than 25%.


3. Workable in outdoor environment.


4. 4-6 hours from installation to use.

Specification

Overall planIT cabinet number2-15 cabinets
MainsSingle  Phase:220Vac,50Hz,1Ph+N+PE
Three  Phase:380Vac,50Hz,3Ph+N+PE
Ambient Temperature﹣20-45℃
IP ClassIP5X
Altitude1000m, derating for>1000m
CabinetDimension(W*D*H)600*1400*2000mm(Without caster)
Display10.1 inch touch screen LCD
LightingFront and rear LED, front Tri-colored LED
Cable entryTop and bottom
Door SecurityFingerprint+IC/ID card+Password
Emergency Methodpop-up door system
Power supply and distribution systemDistribution systemTotal input current63-200A
Thunder protectionC Level
UPSCapacity10kVA-90kVA
Input VoltageSingle  Phase:220Vac,50Hz,1Ph+N+PE;
Three  Phase:380Vac,50Hz,3Ph+N+PE
Operation Mode1(phase in)/ 1(phase out),3/1,3/3
BatteryBattery pack/cabinet
PDUNormal2pcs,16ports(13*C10A + 3*C16 )
IntelligentIntelligent PDU 24 ports (optional)
Refrigeration systemPower SupplyMains power supply
Cooling Capacity3.7-25kW
Installation MethodRack-mount/array can be chosen
Inlet Outlet MethodAir flow out from ahead and circle to back
Compressor TypeVariable frequency
Monitoring systemDynamic Environment MonitoringIntelligent integrated monitoring host
Standard power collection
Environment MonitoringSmoke sensor*1,can have an addition
Temperature&humidity sensor(optional)
Water leakage sensor*1
Webcam(optional)
Infrared detector(optional)
Other Optional AccessoriesSMS alarm(optional)

iSmart Series Integrated Cabinet Solution

Features

Safe and reliable

● All components follow domestic and international standardized production standards to ensure product quality.

● Pre-installation, pre-commissioning and other process are controlled at various levels to ensure product installation and 
operation safe and reliable.

● A single cabinet is a complete system, suitable for various complex scenes (dust, narrow space, no insulation measures, etc.).

● Integrated design, overall delivery, avoid system design problems.

● The emergency cooling fan can delay the channel overheating and reserves time for data backup.

● The cabinet integrates an intelligent monitoring system to ensure the safe and reliable operation of the computer room.

Easy installation and rapid deployment

● Modular design of power distribution, easy installation and maintenance.

● Rack-mounted air conditioner indoor unit, pipe thread connection, easy maintenance.

● The computer room does not need special decoration treatment, and the equipment is ready to use. Installation and commissioning cycle only need 3 hours.

● A single cabinet is a complete system, which can be easily and quickly expanded to 2-3 cabinets side by side.

Efficiency and energy saving

● Proximal refrigeration, high-efficiency power supply, and the overall annual average PUE of single cabinet ≈ 1.30.

● The power distribution, UPS, monitoring, and refrigeration cabinets are integrated to save space.

● Engineering free design, free decoration and wiring, remote operation and maintenance are not on duty, saving TCO.

Intelligent management

● The monitoring system is extensible and compatible with third-party monitoring systems; friendly human-computer interface.

● Support local and remote WEB interface access, SMS alarm function.

Specifications

SystemIT rated power3kVA
Mains220Vac,50Hz/60Hz
Ambient temperature0-45℃
Ambient humidity10-95% (Relative humidity)
IP ClassIP5X
Altitude1000m,  dereating for >1000m
CabinetDimension(W*D*H)600*1200*2000mm(Without caster)
Space occupation≤32U
Display10.1’’ touch screen LCD
Ambient LightFront RGB three-color ambient light
Lighting methodFront and rear LED
Cable entryTop and bottom
Access control systemFingerprint + swipe card(IC&ID) + digital password three in one
Power Supply and Distribution SystemDistribution moduleConfigurationMain CB: 63A/2P, rack installation, with the indicator of operation
Lightning protectionClass C lightning protection (Standard for 2P, optional for 1P+N)
Height3U
UPSCapacity3kVA/6kVA
Power dstribution Single phase in and single phase out
BatteryBuilt-in battery or external battery cabinet
PDUNormal typeIEC C13*2pcs, 16 ports (13*10A+3*16A)
Intelligent typeOptional for 24 ports
Monitoring SystemSupervision systemIntelligent integrated monitoring host
Single cabinetSingle cabinet control module
Eenvironment monitoringsmoke detector*1
Temperature&humidity detector*1
Water leakage detector*1
Webcam(optional)
Infrared detector(optional)
Other detectorSMS alarm (optional)
Emergency VentilationEmergency measuresEmergency pop-up door system
Cooling SystemAir conditionerRack type (Standard for constant temperature)
Rated cooling capacity3.7kW
Rated power consumption1.2kW
Rated air volume700m³/h
Drop height-5m≤△H≤10m
MechanicalPackage dimensions720*1338*2230mm
Weight188kg (without AC, UPS, battery pack)
 Cabinet color Black (RAL9004)
Scroll to Top